cjkas ff7517e10f fix: review findings on the login throttle
- The throttle runs on a 64-bit clock in ms (esp_timer_get_time()), so a
  slot left alone for 49.7 days isn't brought back by millis() wrapping
  round to its old failure.
- Web.cpp turns the client into the throttle's key in one place, and
  says that an IPv6 client would share key 0; names are clearer
  (retryMs, vacantSlot).
- The shared slot's test now succeeds from the IP counted in it, so a
  success that cleared the shared slot would fail it.
- GLOSSARY.md names it the login throttle, with lockouts, and
  SECURITY_PLAN.md and ADR 0006 use that name.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>