- A group's sunSensor and a shade's flags are refused by name: the routes
don't set them.
- setPaired needs paired, and without a shade id it is a bad request.
- groupOptions' payload is parsed in ProtoEdits (parseReadPayload).
- The assembler's mutex is static, so creating it can't fail.
- protoIsReadOp and protoIsShadeOp are gone; the tests use protoOpKind.
- Native tests for missing(), offeredRemoteAddress and the edit ops
against the TYPE table.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
From the review of 7723711:
- The assembler is locked: a client closed for a full queue is closed
by the task that was sending, loop(), whose disconnect dropped the
buffer while async_tcp could be copying into it. A whole message is
taken out of it, so a disconnect can't free it while it is read.
- loop() expires a message stalled for 10 s, freeing its buffer and
telling its client, instead of holding it until another client came.
A binary message is refused before it can touch another's buffer.
- Each edit takes only the fields its route reads; one it would ignore
is refused by name. linkRemote's rolling code goes in under the
route's name, so applyModelEdit is unchanged again.
- An edit refused for an id that doesn't exist replies not found
(edit_result_t::missing). A reply that doesn't fit its buffer goes
as an internal error, so the op still gets one.
- The TYPE table says what becomes of each op (proto_op_t), which the
socket switches on. The reply address is one proto_reply_to_t. The
routes and the ops start and queue an edit the same way
(newModelEdit, submitModelEdit). The full-list texts and the offered
remote address rule live in ModelEditor.
- e2e: the sort order test skips a list that it would renumber.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
From the review of #100:
- setMyPosition on a moving shade replies busy ("The shade is moving"),
and setPositions with only a tilt, for a shade without one, replies
bad request ("The shade has no tilt"). Both said ok before.
- PROTOCOL.md lists where the ops differ from the routes, and how
sendRemoteCommand is answered.
- The LoopQueue hold comment covers protocol 2 replies and an unpair
held through a frequency scan.
- One shadeRequestIsForGroup() for the group cases; ProtoOps shares one
reader for "one or both" fields and one for ids, and the radio
refused text.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
shadeCommand, groupCommand, tiltCommand, repeatCommand, setPositions,
setSensor, setMyPosition, unpairShade, setRollingCode (types 16-24) are
read on async_tcp by ProtoOps and handed to loop() through the
LoopQueue, which replies once the request has run: ok, not found or
radio unavailable. A bad payload, a paused radio or a full queue is
answered straight away. sendRemoteCommand (25) touches nothing of the
shade model, so it goes to the radio from async_tcp like its route.
ShadeRequests::run() now says how a request went, not only whether
the radio took it. An op reads only the fields that were sent, so
setPositions can leave the tilt as it is. The shadeCommand event is
renamed shadeCommanded, since the op has the route's name.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>