Commit graph

2 commits

Author SHA1 Message Date
R. Sid Shaytay
2b3d556729
Show the fixed radio pins as read-only in the web UI
On the integrated-radio board the firmware replaces any radio pins a client
saves with the board's wiring, yet the web UI let the user edit them and
reported success. The radio settings now carry fixedPins (wire key fx),
sent only where the radio is wired to the board. The web UI disables the six
pin selects, shows "Radio wiring is fixed on this board." and skips the pin
duplicate and boot-pin checks for them. Generic builds do not send the
field, so their behaviour is unchanged, and applyBoardPins() stays as the
safety net for old configs and imports.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
2026-11-14 18:41:27 -08:00
cjkas
3212230f01 fix: web UI review findings (step 2b)
- Saving the security settings threw: the form's values were named
  security, hiding the Security object the new token goes to. A save from
  None to None no longer reconnects, as the device closes nobody then.
- Each sync redraws the lists and reloads the settings, so a reconnect
  shows what changed meanwhile; closing the config panel drops its feeds
  even while the socket is down.
- A 401 on backup or an upload opens the login, as a refused socket does
  (Security.tokenRefused); a failed firmware upload says so.
- The general and security panels fill in what the device leaves out at
  its default, so a save never writes back what the form showed before.
  The hostname holds 31 characters, as the device does.
- The views (settings with defaults, a group's shades, frames, scans, the
  network and radio panels, op errors) move to data-src/js/views.js, with
  tests. runOp is the one op path with the busy retry; repeatOf,
  commandArgs, gone(); dead update*List and editedRepeaters removed.
- Tests for ProtoClient.off and a listener removing itself mid-event.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-25 20:43:09 +01:00