Fix RTW decoder: off-by-one in cmd mapping (issue #664)
The RTW protocol decoder used `encKey - 133` to remap the command, but the encoder uses encKey values starting at 133 (My), so the correct offset is 132: - My (encKey=133) → cmd 1 ✓ (previously: 0=Unknown0, unreachable since '> 133') - Up (encKey=134) → cmd 2 ✓ (previously: 1=My) - Down (encKey=136) → cmd 4 ✓ (previously: 3=MyUp) - ... Fixes: linked remote presses now correctly update shade position on RTW motors (Mantion etc.). Tested with ESP32-WROOM-32 + CC1101 V2.0 + 10x Mantion Italian motors. Before: rolling code incremented but position stuck. After: position updates correctly when wall remote is pressed. Refs: #664
This commit is contained in:
parent
eb75868adb
commit
a484307e49
1 changed files with 2 additions and 2 deletions
|
|
@ -156,9 +156,9 @@ void somfy_frame_t::decodeFrame(byte* frame) {
|
||||||
this->proto = radio_proto::RTV;
|
this->proto = radio_proto::RTV;
|
||||||
this->cmd = (somfy_commands)(this->encKey - 148);
|
this->cmd = (somfy_commands)(this->encKey - 148);
|
||||||
}
|
}
|
||||||
else if(this->encKey > 133) {
|
else if(this->encKey >= 133) {
|
||||||
this->proto = radio_proto::RTW;
|
this->proto = radio_proto::RTW;
|
||||||
this->cmd = (somfy_commands)(this->encKey - 133);
|
this->cmd = (somfy_commands)(this->encKey - 132);
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
else this->proto = radio_proto::RTS;
|